What does DOCMA mean in MEDICAL


DOCMA is an acronym that stands for Dynamic Off-Resonance Correction With Multiecho Acquisition. It is a technique used in Magnetic Resonance Imaging (MRI) scans to create more accurate images of the body. DOCMA can be used in both conventional and advanced MRI sequences, such as diffusion-weighted and functional imaging. It helps to reduce artifacts caused by off-resonance and ghosting of signal from tissues containing different concentrations of protons. DOCMA has become an important tool for radiologists in diagnosing diseases and performing research studies with detailed images of anatomy or physiology.

DOCMA

DOCMA meaning in Medical in Medical

DOCMA mostly used in an acronym Medical in Category Medical that means Dynamic Off-Resonance Correction With Multiecho Acquisition

Shorthand: DOCMA,
Full Form: Dynamic Off-Resonance Correction With Multiecho Acquisition

For more information of "Dynamic Off-Resonance Correction With Multiecho Acquisition", see the section below.

» Medical » Medical

Benefits

The use of DOCMA provides several benefits over traditional MRI techniques including improved image clarity; increased signal intensity; greater contrast resolution; reduced false positives; improved motion tracking accuracy; higher temporal resolution; and enhanced accuracy for measuring brain functions such as glutamate neurotransmission dynamics.

Essential Questions and Answers on Dynamic Off-Resonance Correction With Multiecho Acquisition in "MEDICAL»MEDICAL"

What is DOCMA?

DOCMA is an image reconstruction technique that allows reduction of off-resonance artifacts in multi-echo sequences. It uses signals acquired at multiple echo times to create a more accurate map of the tissue's relaxation characteristics, allowing for improved accuracy in imaging parameters such as T1 and T2 values.

How does DOCMA reduce off-resonance artifacts?

DOCMA utilizes signals from multiple echoes during image reconstruction, which supply greater information regarding the phase relationship between different parts of the field of view. This allows DOCMA to better account for off-resonance effects, reducing artifacts and improving the accuracy of imaging parameters.

What type of MRI scans can use DOCMA?

Any multi-echo based sequence can benefit from DOCMA. This includes but is not limited to T1 weighted, T2 weighted, diffusion weighted, and MR angiography sequences.

Does there need to be a specific number of echoes for using DOCMA?

Typically a minimum of 3 echoes are required for a reasonable performance from DOCMA however more echoes will provide more accurate results. Generally speaking, 4-6 echoes should provide sufficient information for most applications.

Is there any additional hardware or software needed for using DOCMA?

Other than the regular MRI system components, no additional hardware is necessary for using DOCMA. You will however need supported software that allows you to enable DOCMA as part of your acquisition sequence.

Are there any safety considerations when using DOC MA?

With the addition of extra measurement elements withDOC MA enabled acquisitions, it is important to verify that all safety protocols are complied with prior to proceeding with scanning patients or volunteers. Also ensure that adequate patient monitoring systems are in place when running deeper analyses such as off resonance correction with multiecho acquisitions (DOC MA).

What kind of improvements can we expect from using DO CMA?

Clinically relevant benefits including more accurate measurements of T1 andT2 values at higher SNR can be expected when utilizing DO CMA over conventional techniques depending on the application being used.

Final Words:
In conclusion, DOCMA is an acronym that stands for Dynamic Off-Resonance Correction With Multiecho Acquisition and is a valuable tool for improving MRI imaging quality for both diagnostic imaging and research studies. It allows radiologists to get more accurate images without having to compromise on image quality due to off-resonance effects caused by differences in proton concentration among tissues being imaged. The use of DOCMA can also provide greater contrast resolution, better motion tracking accuracy, and improved temporal resolution compared to traditional single echo imaging techniques.

Citation

Use the citation below to add this abbreviation to your bibliography:

Style: MLA Chicago APA

  • "DOCMA" www.englishdbs.com. 26 Dec, 2024. <https://www.englishdbs.com/abbreviation/224909>.
  • www.englishdbs.com. "DOCMA" Accessed 26 Dec, 2024. https://www.englishdbs.com/abbreviation/224909.
  • "DOCMA" (n.d.). www.englishdbs.com. Retrieved 26 Dec, 2024, from https://www.englishdbs.com/abbreviation/224909.
  • New

    Latest abbreviations

    »
    O
    Ontology Based Information Extraction Systems
    S
    Selfish Tyrant Aiming Ridiculous Measures Everywhere Remorselessly
    R
    Research Administration Improvement Team
    J
    Jollibee Group Foundation
    T
    Trial Period