What does LDIM mean in CANCER


LDIM stands for Laser Desorption/Ionization Mass Monitoring. In medical terms, LDIM is used to measure the size of particles such as proteins and peptides. The technique uses a laser beam to disassociate molecules present in solution, and then measure the mass of the resulting ions with an ion detector. This method enables scientists to identify biomolecules based on their mass-to-charge ratio and can be used for biological research, pharmaceutical development, and molecular diagnostics.

LDIM

LDIM meaning in Cancer in Medical

LDIM mostly used in an acronym Cancer in Category Medical that means Laser Desorption/Ionization Mass Monitoring

Shorthand: LDIM,
Full Form: Laser Desorption/Ionization Mass Monitoring

For more information of "Laser Desorption/Ionization Mass Monitoring", see the section below.

» Medical » Cancer

Working Principle

LDIM works by irradiating a particle or molecule with a high intensity pulse of laser light. This results in desorption or fragmentation of the particle into smaller ions that can be detected by an ion detector. The primary benefit of this process is that it enables scientists to quickly identify organic molecules based on their mass-to-charge ratio, which cannot be easily determined through other methods.

Advantages

There are several advantages to using LDIM over traditional methods for determining molecular weight. For instance, LDIM has a higher resolution than conventional light spectroscopy techniques, meaning that it can detect very small differences in mass between two molecules. Additionally, it can be used to quickly analyze large numbers of samples at once instead of having to analyze each sample individually. Furthermore, since LDIM does not require the use of solvents or other chemicals during analysis, it is much less labor intensive than other techniques such as chromatography or electrophoresis. Finally, because LDIM is non-destructive and non-invasive, it does not interfere with or affect the structure of analyzed molecules like some other techniques do.

Applications

LDIM has several applications in biomedical research and drug discovery due to its wide range of detection capabilities and its ability to analyze multiple samples at once quickly and accurately. For instance, it has been utilized for protein identification based on their size, studying enzyme activities related to disease states or drug targets, analyzing polysaccharide structures related to immune response activities, identifying biomarkers associated with various conditions such as cancer or cardiovascular disease, and screening drug molecules before they enter clinical trials – all without damaging the molecule being examined.

Essential Questions and Answers on Laser Desorption/Ionization Mass Monitoring in "MEDICAL»CANCER"

What is LDIM?

Laser Desorption/Ionization Mass Monitoring (LDIM) is a process in which ions are produced from sample material by laser ablation, and the ionic species created are monitored with an ion mass spectrometer.

How does LDIM work?

In LDIM, a sample material is placed on a substrate plate and an infrared or ultraviolet laser beam is then focused on the material. The energy from the laser beam produces small particles or droplets of the material which are then propelled into the gas phase. An ion mass spectrometer detects the ions created from these droplets and measures their mass-to-charge ratio to characterize them.

Is LDIM effective?

Yes, LDIM is highly effective for identifying and quantifying components of complex mixtures such as polymers, biopolymers, and biological fluids since the technique can provide accurate quantitative data relating to the individual components in a mixture.

What kinds of samples can be analyzed with LDIM?

Nearly any type of sample that can hold within its structure molecules or atoms capable of emitting ions upon ablation may be suitable for analysis via LDIM. These include complex biological fluids such as blood, saliva, urine; organic polymers; pharmaceuticals; petrochemicals; forensics materials; food products etc.

How many ions can be detected with LDIM?

Typically millions of ions may be detected simultaneously in each run using this technique.

Are there any advantages to using LDIM?

Yes, some primary advantages of using this method include its capability to analyze complex mixtures without prior separation steps, its accuracy in characterizing different compounds present in a sample according to their advanced characteristics (such as isotopic distribution), and its ability to quantify multiple analytes at trace levels simultaneously.

Is there any limitations associated with LDIM?

One limitation associated with this analytical technique is that it cannot produce high resolution data due to the nature of how it works - only masses up to 3000 Daltons are possible making it unsuitable for certain types of molecules which require higher resolution data. Additionally, sample materials must be prepared before being analyzed by standard protocols which could also lead to time constraints when analyzing large numbers of samples in a short period of time.

Final Words:
LDIM is a powerful technique used in biomedical research for measuring the size and mass of particles such as proteins and peptides without damaging them in any way. Its non-destructive nature allows scientists to gain detailed insight into these molecules’ structures while avoiding any unwanted side effects caused by other methods such as chromatography or electrophoresis. It also offers rapid batch analysis capabilities that make it ideal for large scale drug development projects involving hundreds or even thousands of samples simultaneously.

Citation

Use the citation below to add this abbreviation to your bibliography:

Style: MLA Chicago APA

  • "LDIM" www.englishdbs.com. 22 Dec, 2024. <https://www.englishdbs.com/abbreviation/1171006>.
  • www.englishdbs.com. "LDIM" Accessed 22 Dec, 2024. https://www.englishdbs.com/abbreviation/1171006.
  • "LDIM" (n.d.). www.englishdbs.com. Retrieved 22 Dec, 2024, from https://www.englishdbs.com/abbreviation/1171006.
  • New

    Latest abbreviations

    »
    V
    VAriable Specific Impulse Magnetoplasma Rocket
    M
    Multifactor Emotional Intelligence Scale
    T
    Taconic Health Information Network and Community
    Z
    Zero Energy House
    C
    China International Telecommunication Construction Corporation